USB power meter U2062XA
Frequency range: 10 MHz–18 GHz
USD · Оптовые цены
Категории:
Сертификаты
Доставка 7-14 дней
DHL/FedEx/UPS/авиа/море
Оригинал гарантирован
Официальные поставщики
Полный пакет документов
ECCN, CO, CI, PL, EUS docs
Поддержка 24/7
До и после продажи
Экспортный контроль
EAR99AI уверенность 100% · NLR — Лицензия не требуется. Рекомендуется заявление о конечном использовании.
Программа лояльности
Скидка по уровню суммируется с оптовыми ценами
Order the Keysight U2062XA USB Power Meter to accurately monitor your FPV transmitters!
Measure the output power of video transmitters and antennas with laboratory precision. The compact USB device connects to your laptop and is ready to use in seconds. Wide frequency range covers all popular FPV frequencies. Choose a professional tool for configuration and diagnostics.
-
Wide frequency range 10 MHz–18 GHz. Measures power on all FPV bands from 2.4 GHz to 5.8 GHz and above.
-
High dynamics -70…+26 dBm. Allows you to measure both weak signals and powerful transmitters without attenuators.
-
Internal calibration and zeroing. Provides high accuracy without external measures or adjustments.
-
Analysis of pulse signals. Measures the duration, repetition rate and shape of single pulses.
-
Easy to connect and small in size. Operates via USB without external power, ideal for field conditions.
Operating principle and key features
The U2062XA power meter is a USB-controlled sensor with wide dynamic range. It connects to your computer via USB and does not require an external power source. The device measures average, peak and pulse signal power. The built-in processor performs calibration and temperature compensation. A sampling rate of 20 million samples per second allows analysis of fast processes.
The meter is capable of capturing single pulses with a duration of 250 nanoseconds. The signal rise time is no more than 100 nanoseconds. This allows you to accurately measure the power of signals with fast edges. The device supports continuous data acquisition for 1 second in compressed mode and 6.5 milliseconds in full mode. The maximum pulse repetition rate reaches 2 MHz.
Use the meter to check the actual VTX output power, tune antennas, and measure gain. The device is indispensable for diagnosing range and interference problems. The compact size allows you to take it into the field for operational measurements.
Specifications
- Frequency range: 10 MHz–18 GHz
- Power range: -70…+26 dBm
- Connector: N-type (male)
- Maximum power: average +29 dBm; peak +32 dBm (<10 µs)
- Voltage: ≤10V DC
- Zeroing/Calibration: Internal
- Sampling rate: 20 MSa/s (continuous)
- Single pulse bandwidth: 5 MHz
- Min. Pulse duration: 250 ns
- Rise/fall time: ≤100ns
- Max. capture duration: 1 s (compressed); 6.5 ms (full)
- Pulse repetition frequency: up to 2 MHz.